CVE-2025-59098
中文标题:
(暂无数据)
英文标题:
Trace Functionality Leaking Sensitive Data in dormakaba access manager
漏洞描述
中文描述:
(暂无数据)
英文描述:
The Access Manager is offering a trace functionality to debug errors and issues with the device. The trace functionality is implemented as a simple TCP socket. A tool called TraceClient.exe, provided by dormakaba via the Access Manager web interface, is used to connect to the socket and receive debug information. The data is permanently broadcasted on the TCP socket. The socket can be accessed without any authentication or encryption. The transmitted data is based on the set verbosity level. The verbosity level can be set using the http(s) endpoint with the service interface password or with the guessable identifier of the device via the SOAP interface. The transmitted data contains sensitive data like the Card ID as well as all button presses on Registration units. This allows an attacker with network level access to retrieve all entered PINs on a registration unit.
CWE类型:
标签:
受影响产品
| 厂商 | 产品 | 版本 | 版本范围 | 平台 | CPE |
|---|---|---|---|---|---|
| dormakaba | Access Manager 92xx-k5 | 92xx-K5: <XAMB 04.06.212 | - | - |
cpe:2.3:a:dormakaba:access_manager_92xx-k5:92xx-k5:_<xamb_04.06.212:*:*:*:*:*:*:*
|
| dormakaba | Access Manager 92xx-k7 | 92xx-K7: <BAME 05.02.156 | - | - |
cpe:2.3:a:dormakaba:access_manager_92xx-k7:92xx-k7:_<bame_05.02.156:*:*:*:*:*:*:*
|
解决方案
中文解决方案:
英文解决方案:
临时解决方案:
CVSS评分详情
4.0 (cna)
HIGHCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
时间信息
利用信息
数据源详情
| 数据源 | 记录ID | 版本 | 提取时间 |
|---|---|---|---|
| CVE | cve_CVE-2025-59098 |
2026-01-27 03:17:06 | 2026-01-26 22:00:06 |
| NVD | nvd_CVE-2025-59098 |
2026-01-27 02:00:07 | 2026-01-26 22:00:15 |
版本与语言
安全公告
变更历史
查看详细变更
- data_sources: ['cve'] -> ['cve', 'nvd']